Converter suite

PLC data converters for controls engineers.

Compare PLC values across signed, unsigned, REAL, BCD, ASCII, endian, string, Modbus, byte, word, and bit representations.

DINT Data Converter

Convert a 32-bit value into signed, unsigned, hex, binary, byte, word, and bit views.

Detected: decimal
Examples

Register Views

Useful when comparing PLC tags, Modbus registers, and vendor byte ordering.

Signed DINT
12345
Unsigned DWORD
12345
Hex
16#00003039
Bytes
00 00 30 39
High Word
16#0000
Low Word
16#3039
Binary
0000 0000 0000 0000 0011 0000 0011 1001

Bit Viewer

0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31

Endian and Swap Views

Big Endian
00 00 30 39
Little Endian
39 30 00 00
Word Swap
30 39 00 00
Byte Swap
00 00 39 30
Byte + Word Swap
39 30 00 00

PLC data tools locked

DINT conversion accepts one preview value in automatic format. Manual formats, REAL conversion, PLC format converters, Modbus register workflows, width helpers, string layouts, endian/platform review notes, and batch workflows require an active Toolkit or Pro Toolkit entitlement.

Requires Toolkit or Pro Toolkit

Advanced PLC data utilities

Free preview

Enter one DINT value in automatic format and watch its real signed, unsigned, hex, binary, byte, word, bit, and swap results update.

Paid operation

Manual formats, REAL conversion, legacy formats, endian and Modbus tools, batch conversion, and guided register review require paid access.

Unlocks with Toolkit or Pro Toolkit
  • Manual DINT and REAL formats
  • Endian comparison workflow
  • Copy/export-ready output
View account options

Entitlement store: unavailable. No saved presets, saved settings, or customer tool history are stored in V1.

Included converter set

Every listed utility is implemented; access labels indicate the subscription boundary.

DINT / DWORD Converter

Preview publicly; live signed, unsigned, hex, binary, byte, word, bit, and swap views require Toolkit.

IEEE754 REAL Converter

Toolkit: decimal, hex, binary, sign, exponent, mantissa, and swap views.

Endian Converter

Toolkit: byte, word, byte+word, little-endian, and Modbus-friendly views.

Modbus Register Viewer

Toolkit: 40001 mapping, word pairs, REAL, DINT, DWORD, INT, and UINT views.

PLC Format Converters

Toolkit: BCD, ASCII bytes, Gray code, and octal helpers.

String Tools

Toolkit: ASCII arrays, null termination, Rockwell STRING, and Siemens headers.

Platform Notes

Toolkit: interpretation reminders across major PLC platforms.