Find tools, articles, and downloads from one place.
Search across calculators, PLC data utilities, troubleshooting guides, product downloads, and site pages.
Browse index
110 results
0-10 V Analog Signal Simulator
Run, pause, and fault a virtual voltage channel while watching 0-10 V, raw counts, and engineering units move together.
24 VDC Load Budget
Build a local load list with inrush, utilization, and design margin
4-20 mA Loop Simulator
Run, pause, and fault a virtual transmitter while watching current, raw counts, and engineering units respond.
4-20 mA Scaling
Convert raw input counts to engineering units
4-20 mA scaling formula and worked examples
Use the linear 4-20 mA scaling equation without losing the live-zero offset, engineering units, or fault-range behavior at the ends of the signal.
4-20 mA scaling, shunt resistors, raw counts, and signal diagnostics
A practical 4-20 mA reference for linear scaling, 250 and 500 ohm shunt resistors, Allen-Bradley and Siemens raw values, live-zero behavior, and signal diagnostics.
4-20 mA shunt resistor selection: 250 ohm and 500 ohm examples
Convert a 4-20 mA loop into a voltage signal with Ohm's Law while checking resistor power, input impedance, loop burden, tolerance, and existing receiver hardware.
4-20 mA underrange and overrange troubleshooting
Separate valid extended measurement, NAMUR-style fault indications, open-loop behavior, saturation, and PLC clamping when a 4-20 mA value leaves its nominal span.
Account
Contact page for future validated form and notification routing.
Advanced electrical review tools
Deeper motor, protection, voltage-drop, and transformer review flows for repeatable controls-panel checks.
Alarm Triage and Handoff Tool
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Allen-Bradley analog raw counts and engineering-unit scaling
Identify the actual Allen-Bradley module data representation before scaling raw integer counts, floating-point channel data, alarms, and overrange indicators.
Analog Signal Workbench
Forward and inverse scaling across raw counts, live-zero signals, percentage, and engineering units
Backup Readiness Scorecard
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Batch PLC data converter
Paste a list of register values and compare decimal, hex, binary, byte order, word order, and Modbus interpretations in one pass.
Calculators
Scaling, power, braking, 24 VDC budget, voltage-drop, time-correlation, and network calculations
Commissioning evidence helper
Pair analog scaling checks with expected ranges, pass/fail notes, and field evidence prompts for startup documentation.
Commissioning Workbench
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Common three-phase formula mistakes
Catch phase-count, voltage-basis, unit, power-factor, efficiency, and load-model mistakes before a three-phase calculator result reaches a design or troubleshooting decision.
CompactLogix controller fault recovery
Preserve and interpret CompactLogix controller state, major-fault evidence, startup behavior, storage, I/O status, and project identity before attempting recovery.
Configuration Manifest Builder
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Contact
Contact page for future validated form and notification routing.
Continuous Conveyor Control Simulator
Start and stop a continuously looping conveyor while part position, transfer count, belt speed, and a selectable 4-20 mA or 0-10 V drive reference move together.
Controller communications inventory
A single reference for controller interfaces, peer connections, messages, serial links, gateways, protocols, switches, and ports.
ControlLogix DHRIO DH+ and Remote I/O troubleshooting
Isolate 1756-DHRIO communication failures by preserving channel mode, rotary-switch and baud settings, link IDs, routing tables, rack addressing, block transfers, retries, and physical blue-hose evidence.
ControlNet coax fault isolation
Isolate ControlNet coax segment, tap, terminator, connector, shield, node, repeater, and scheduling faults using a physical boundary map and preserved module diagnostics.
Converters
Translate PLC values and inventory browser-local L5K project metadata without uploading a project
DeviceNet physical network fault isolation
Isolate DeviceNet power, termination, trunk, drop, connector, baud-rate, node-address, and scanner faults while preserving the healthy-to-failed network boundary.
DINT Data Converter
Convert one 32-bit PLC value into signed, unsigned, hexadecimal, binary, byte, word, bit, and swap views.
DINT Two's Complement: FFFFFFFC = -4
Decode hexadecimal values such as FFFFFFFC (-4) and FFFFFFFF (-1), then distinguish signed DINT, unsigned data, and bit masks before PLC conversion or comparison.
Downtime Incident Builder
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Drive Deceleration and Braking Estimator
Estimate rotating energy, average braking torque, power, and review cautions
Duplicate IP diagnosis on industrial networks
Use ARP, MAC-address changes, switch-port evidence, device identity, and controlled isolation to prove a duplicate IPv4 address without random power cycling.
Engineering Tools
Browse automation calculators and utilities for PLC data, electrical work, networking, and scaling.
ET 200 remote-I/O LED and configuration diagnostics
Turn ET 200 BF, SF, ER, MT, RUN, and power indications into a controlled fault-isolation path by matching the exact interface module, firmware, configuration, backplane, and field-channel diagnostics.
EtherNet/IP connection troubleshooting
Separate physical-link, IP, CIP connection, RPI, multicast, ownership, and controller-logic problems when an EtherNet/IP device faults or reconnects.
EtherNet/IP Device Level Ring fault isolation
Diagnose a degraded or faulted DLR network by proving supervisor identity, ring topology, port roles, last active nodes, fault location, speed, multicast load, gateway state, and physical media.
FactoryTalk backup checklist
A recoverability checklist for FactoryTalk and Allen-Bradley systems where a copied project file is not enough to restore production.
FactoryTalk Linx health
A structured checklist for FactoryTalk Linx shortcuts, drivers, services, FactoryTalk Directory scope, diagnostics, OPC UA/Gateway access, and backup evidence.
Field Workflows
Build browser-local commissioning, incident, change, backup, network, I/O, alarm, manifest, dependency, and maintenance records
Free 3-Phase Current Calculator
Estimate single-phase or three-phase load current from kW, voltage, and power factor
HMI tag and alarm cross-reference
A structured map between HMI displays, PLC tags, commands, alarms, trends, recipes, units, limits, access roles, and ownership.
I/O Checkout Generator
Build, restore locally, reset, and download a formatted PDF field record without server storage.
I/O point documentation and checkout register
A rack-to-field record for modules, digital points, analog signals, scaling ownership, spares, and drawing reconciliation.
Industrial Network Evidence Pack
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Industrial Network Switch Troubleshooting Guide
A practical guide to troubleshooting industrial network switches, including power and link checks, port errors, duplex mismatches, duplicate IPs, VLAN boundaries, multicast, and EtherNet/IP faults.
Industrial network troubleshooting flow
Walk through IP, subnet, switch, multicast, and protocol checks with a structured evidence trail.
Industrial Networking Toolkit
Inspect a fixed subnet example and unlock editable inputs plus guided EtherNet/IP, addressing, MAC, range, and evidence workflows.
Industrial networking, subnet, VLAN, and EtherNet/IP diagnostics
A practical industrial Ethernet reference for subnet boundaries, duplicate IP evidence, VLAN routing, and EtherNet/IP connection troubleshooting.
Industrial subnet worked examples
Calculate network, broadcast, usable-host range, and same-subnet decisions for common industrial IPv4 prefixes before changing a controller or device address.
IP address and ping verification chart
A clean, repeatable record for device identities, approved IP settings, ping runs, physical paths, and baseline exceptions.
L5K PLC Tag and Routine Explorer
Open a text L5K export locally and inventory controller/program tags, aliases, routines, descriptions, data types, initial values, and suggested field roles.
Logix Add-On Instruction instance and parameter troubleshooting
Trace unexpected AOI behavior through call execution, instance data, parameter direction, InOut references, prescan or enable-state handling, signatures, and imported-definition revisions.
Logix EtherNet/IP I/O connection troubleshooting
Diagnose faulted Logix I/O connections by separating controller ownership, module identity, electronic keying, path, RPI, capacity, link, and field-device evidence.
Logix MSG instruction path and error troubleshooting
Diagnose Logix explicit-message failures by preserving status words, validating the communication path segment by segment, and separating trigger logic, connection resources, routing, and destination service errors.
Logix produced and consumed tag connection troubleshooting
Diagnose stale or faulted controller-to-controller data by proving producer identity, controller paths, tag scope, matching data layouts, connection status, RPI, and network capacity.
Logix task scan, overlap, and watchdog troubleshooting
Trace missed updates, periodic-task overlap, long scans, and watchdog faults by proving task scheduling, priority, execution time, program order, and the code path that actually ran.
Maintenance Window Planner
Build, restore locally, reset, and download a formatted PDF field record without server storage.
MicroLogix 1400 backup, restore, and replacement commissioning
Prepare and validate a MicroLogix 1400 replacement by preserving the complete project and data state, matching hardware and firmware, restoring communications, and proving I/O and machine behavior.
MicroLogix 1400 communications recovery
Recover MicroLogix 1400 Ethernet and serial access by proving channel mode, protocol, address, cabling, routing, and controller state without overwriting the application.
Modbus register addressing and value interpretation
Resolve 40001 notation, zero-based protocol offsets, function codes, signed values, and multi-register data before blaming communication quality.
Modbus RTU serial commissioning and timeout troubleshooting
Commission and troubleshoot a Modbus RTU segment by proving the EIA-485 physical layer, unique unit IDs, baud and framing, request timing, CRC-valid responses, function codes, register offsets, and data interpretation.
Motor Starter and Interlock Simulator
Step seal-in logic, Manual and Auto requests, stop priority, overloads, permissives, custom tag names, run feedback, and injected starter faults.
Network Address Plan Builder
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Network troubleshooting sheet
A downtime-friendly worksheet for diagnosing industrial Ethernet and EtherNet/IP faults while preserving the evidence needed for a real fix.
Ohm's Law Calculator
Solve voltage, current, resistance, and power from two known values
Online PLC Trainer for RSLogix 500-Style Ladder Logic
Build ladder logic in a browser-based RSLogix 500-style workspace and prove it against PLC-memory-driven conveyor, tank, traffic, garage, sorting, paint, parking, and palletizer I/O worlds.
PanelView Plus application and communication recovery
Recover PanelView Plus and FactoryTalk View ME operation by preserving terminal identity, runtime files, communications, shortcuts, firmware, storage, and transfer evidence.
PanelView Standard communication and application recovery
Recover a legacy PanelView Standard terminal by separating terminal power and mode, runtime network settings, application-transfer settings, controller communication, and the last known good application file.
PLC checkout template
A commissioning record for proving PLC-controlled equipment before startup risk becomes downtime, finger-pointing, or an undocumented handoff.
PLC Data Converter Suite
Preview DINT conversion and unlock live DINT, REAL, BCD, ASCII, Gray code, endian, string, and Modbus utilities.
PLC DINT, Modbus register, and REAL data interpretation
A field reference for signed and unsigned 32-bit values, byte and word order, Modbus register offsets, and IEEE 754 REAL conversion.
PLC PID loop commissioning and oscillation troubleshooting
Commission and stabilize a PLC PID loop by proving process-variable health, engineering scaling, execution period, control action, mode and ownership, output limits, valve behavior, process dynamics, and tuning evidence.
PLC program change and backup log
A chronological record linking approved PLC and HMI changes to files, revisions, online edits, temporary conditions, backups, and evidence.
PLC REAL and IEEE 754 conversion checks
Decode a 32-bit single-precision floating-point value only after proving the source bytes, word order, special values, and expected engineering range.
PLC Scan Cycle Simulator
Step through input sampling, logic execution, output updates, and housekeeping to see when state changes become visible.
PLC tag and alias documentation register
A controller-data register for documenting base tags, alias targets, external consumers, ownership, renames, and revisions.
PLC word order and byte order troubleshooting
Separate byte swaps from 16-bit word swaps when PLCs, HMIs, gateways, historians, and Modbus devices exchange 32-bit integers or floating-point values.
PowerFlex 520 commissioning and fault isolation
Commission and troubleshoot PowerFlex 523/525 drives by preserving motor, command, reference, parameter, fault-history, network, and load evidence before reset or replacement.
PowerFlex 750 startup and fault isolation
Commission or recover PowerFlex 753 and 755 drives by proving drive identity, power and motor data, start and reference ownership, option-port configuration, feedback, limits, and fault evidence.
PowerFlex fault triage
A field-first workflow for PowerFlex drive faults, including what to capture before clearing the fault and how to separate line, load, thermal, wiring, safety, and network causes.
Pre-Change Readiness Tool
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Pro Toolkit Library overview
A free buyer's guide to the Pro Toolkit Library, showing the problems each paid field document solves before a customer commits.
PROFIBUS DP segment and slave fault isolation
Isolate PROFIBUS DP bus faults with topology, master diagnostics, slave address and identity, termination, connector, shield, cable, and repeatable segment evidence instead of blind power cycling.
PROFINET device-name and IP commissioning
Commission or replace a PROFINET IO device by proving MAC identity, station name, IP parameters, topology, and controller assignment without treating an IP response as complete PROFINET ownership.
RSLogix 500-style PLC Trainer
Build, monitor, force, save, and test ladder logic against animated industrial I/O worlds driven directly by the controller memory model.
S7-1200 and S7-1500 analog signal commissioning
Commission and diagnose Siemens analog channels by proving wiring, measurement type, range, raw representation, diagnostics, normalization, scaling, smoothing, and engineering-unit behavior.
S7-1500 diagnostic buffer and system diagnostics workflow
Use TIA Portal, the CPU display, web server, HMI, and diagnostic buffer to preserve the event sequence behind a STOP, module fault, or intermittent system alarm before resetting the evidence.
S7-300 and S7-400 CPU STOP diagnostics
Diagnose a classic SIMATIC CPU STOP by preserving the diagnostic-buffer sequence and separating programming, cycle-time, I/O access, rack, module, communication, memory, and hardware events.
Sequence Troubleshooting Simulator
Test conveyor-transfer, clamp, and tank sequences with selectable states, timeouts, permissives, feedback, and injected faults.
Siemens 0-27648 analog scaling with NORM_X and SCALE_X
Work from Siemens analog integer representation to normalized and engineering-unit values while keeping unipolar, bipolar, overflow, and underflow ranges distinct.
Siemens Comfort Panel backup, restore, and replacement recovery
Build and validate a SIMATIC Comfort Panel recovery package by separating editable project sources, device backups, image compatibility, licenses, recipes, archives, communications, and replacement hardware.
Simulators
Explore analog signals, PLC scans, sequences, continuous conveyors, motor starters, and tank-level behavior with clear boundaries
Single-phase current calculation from kW, voltage, and power factor
Calculate single-phase AC current from real power, load voltage, and power factor while avoiding phase-factor, unit, motor-efficiency, and equipment-sizing mistakes.
SLC 500 and MicroLogix data-file addressing field guide
Interpret legacy file-based addresses, timer and counter elements, status bits, indexed or indirect references, and I/O locations without confusing a displayed address with its runtime meaning.
SLC 500 processor fault and status recovery
Recover an SLC 5/03, 5/04, or 5/05 from CPU fault or unexpected mode by preserving status-file evidence and separating program, chassis, power, memory, I/O, and processor causes.
STEP 7 Classic to TIA Portal migration readiness
Prepare a STEP 7 V5.x project for migration by proving source completeness, consistency, option packages, hardware support, protected blocks, HMI dependencies, communications, and rollback evidence.
Subnet Calculator
Plan masks, usable hosts, broadcast, and ranges
System Dependency Map
Build, restore locally, reset, and download a formatted PDF field record without server storage.
Tank Level Control Simulator
Run manual or automatic tank inlet/outlet flow control while mapping the moving level through a selectable 4-20 mA or 0-10 V transmitter and PLC raw input.
ThinManager terminal boot
A boot and connection checklist for ThinManager terminals, covering PXE, DHCP options, TFTP, firmware packages, RDS targets, DNS, firewall paths, and redundancy evidence.
Three-phase current examples at 208, 240, and 480 volts
Use line-to-line voltage, real power, efficiency, and power factor consistently when comparing three-phase current at common industrial system voltages.
Three-phase current, motor estimates, and power-factor formulas
A controls-engineering reference for three-phase current at 208, 240, and 480 V, motor estimates, power factor, and common formula errors.
Three-phase motor current estimation
Estimate motor input current from horsepower or kilowatts while keeping efficiency, power factor, rated voltage, nameplate current, and code sizing tables in their proper roles.
Three-phase power-factor cautions
Keep real power, reactive power, apparent power, displacement power factor, and nonlinear-load distortion distinct when estimating three-phase current or correction needs.
Time and Event Correlation
Normalize clock offsets, sort events, calculate elapsed time, and export a timeline
Toolkits
Combine subnet, address, MAC, EtherNet/IP, protocol, and evidence utilities in one working area
Troubleshooting
Move from symptoms to evidence across FactoryTalk, PowerFlex, industrial Ethernet, and ThinManager
VLAN and subnet boundaries for controls networks
Distinguish Layer 2 VLAN membership from Layer 3 IP subnetting when a controller, HMI, remote I/O device, or engineering workstation cannot reach its peer.
Voltage-Drop and Conductor Check
Estimate voltage drop for copper or aluminum DC, single-phase, and three-phase circuits